Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Braz Dent J ; 34(2): 129-135, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37194851

RESUMO

This study aimed to assess and correlate initial surface roughness and frictional resistance of rectangular CuNiTi wires inserted in different self-ligating brackets. The sample consisted of 40 bracket-wire sets (rectangular CuNiTi wires of 0.017" x 0.025" and passive self-ligating brackets) divided into four groups (n=10): metallic self-ligating bracket and metallic CuNiTi wire (G1); metallic self-ligating bracket and rhodium-coated CuNiTi wire (G2); esthetic self-ligating bracket and metallic wire (G3); esthetic self-ligating bracket and rhodium-coated CuNiTi wire (G4). The initial surface roughness of the wires was examined with a Surfcorder roughness meter, model SE1700. Later, frictional resistance was assessed in an Instron 4411 universal testing machine at a speed of 5 mm/min, in an aqueous medium at 35°C. Microscopic analyses of surface morphology were performed with scanning electron microscopy, using an LEO 1430, with magnifications of 1000X. Generalized linear models were applied, considering the 2 x 2 factorial (bracket type x wire type), at a 5% significance level. Regardless of bracket type, the groups with esthetic wires presented higher initial surface roughness than the groups with metallic wires (p<0.05). There was no significant difference between the different bracket-wire sets for frictional resistance and no significant correlation between frictional resistance and initial surface roughness in the environment studied. It is concluded that esthetic wires presented higher initial surface roughness but did not interfere with the frictional resistance between brackets and wires.


Assuntos
Braquetes Ortodônticos , Ródio , Fios Ortodônticos , Desenho de Aparelho Ortodôntico , Análise do Estresse Dentário , Teste de Materiais , Aço Inoxidável , Propriedades de Superfície , Ligas Dentárias , Titânio
2.
Braz. dent. j ; 34(2): 129-135, Mar.-Apr. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1439573

RESUMO

Abstract This study aimed to assess and correlate initial surface roughness and frictional resistance of rectangular CuNiTi wires inserted in different self-ligating brackets. The sample consisted of 40 bracket-wire sets (rectangular CuNiTi wires of 0.017" x 0.025" and passive self-ligating brackets) divided into four groups (n=10): metallic self-ligating bracket and metallic CuNiTi wire (G1); metallic self-ligating bracket and rhodium-coated CuNiTi wire (G2); esthetic self-ligating bracket and metallic wire (G3); esthetic self-ligating bracket and rhodium-coated CuNiTi wire (G4). The initial surface roughness of the wires was examined with a Surfcorder roughness meter, model SE1700. Later, frictional resistance was assessed in an Instron 4411 universal testing machine at a speed of 5 mm/min, in an aqueous medium at 35°C. Microscopic analyses of surface morphology were performed with scanning electron microscopy, using an LEO 1430, with magnifications of 1000X. Generalized linear models were applied, considering the 2 x 2 factorial (bracket type x wire type), at a 5% significance level. Regardless of bracket type, the groups with esthetic wires presented higher initial surface roughness than the groups with metallic wires (p<0.05). There was no significant difference between the different bracket-wire sets for frictional resistance and no significant correlation between frictional resistance and initial surface roughness in the environment studied. It is concluded that esthetic wires presented higher initial surface roughness but did not interfere with the frictional resistance between brackets and wires.


Resumo O objetivo deste estudo foi avaliar e correlacionar a rugosidade superficial inicial e a resistência a fricção dos fios CuNiTi retangulares inseridos em diferentes bráquetes autoligados. A amostra foi composta por 40 conjuntos bráquetes-fios (fios retangulares CuNiTi de 0.017" x 0.025" e braquetes autoligados passivos), divididos em 4 grupos (n=10): bráquete autoligado metálico e fio CuNiti metálico (G1); braquete autoligado metálico e fio CuNiti com revestimento de rhodium (G2); bráquete autoligado estético e fio metálico (G3); bráquete autoligado estético e fio CuNiti com revestimento de rhodium (G4). A rugosidade superficial inicial do fio foi examinada com um rugosímetro Surfcorder modelo SE1700. Posteriormente, a resistência a fricção foi avaliada em uma máquina de ensaios universal Instron 4411, a uma velocidade de 5mm/min em meio aquoso à 35oC. Análises microscópicas da morfologia de superfície foram realizadas por microscopia eletrônica de varredura, utilizando um LEO 1430, com ampliações de 1000X. Foram aplicados modelos lineares generalizados, considerando o fatorial 2 x 2 (tipo de bráquete x tipo de fio), com o nível de significância de 5%. Independentemente do tipo de bráquete, os grupos com fios estéticos apresentaram maior rugosidade superficial inicial que os grupos com fios metálicos (p<0,05). Não houve diferença significativa entre os diferentes conjuntos bráquetes-fios quanto a resistência à fricção e não houve correlação significativa entre a resistência a fricção e a rugosidade superficial inicial no ambiente estudado. Conclui-se que os fios estéticos apresentaram maior rugosidade superficial inicial porém não interferiram na resistência a fricção entre os braquetes e os fios.

3.
Braz Dent J ; 33(5): 55-63, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36287499

RESUMO

A new device was developed to enable the visualization and measurement of canine angulation while at the same time visualizing and measuring the force transmitted to adjacent teeth. This study aimed to evaluate the mesiodistal tilt angle of the upper canine brackets, the wire deflection, and its effects on adjacent teeth with five different slot designs of upper canines. Wires (0.020" and 0.019" x 0.025") were tested on different five bracket types at five different distal angles. The force applied to adjacent teeth was measured as the angle was increased, and its consequences were observed in the posterior and anterior regions as well. The force tension (gf) was measured in a universal testing machine. Data were submitted to a 3-way ANOVA and Tukey's test (α=0.05). For both arches, regardless of the type of tooth and bracket type, the highest means tension mean values were shown by the 20° angle, followed by the 15°,10°, and 5° angles, which differed statistically among themselves. Overall, for 5°, 10°, and 15° angles, conventional and versatile brackets showed significantly higher force values in all teeth, tip-edge and control brackets showed the lowest. The highest force values were observed in central and lateral incisors with conventional and versatile brackets and on first and second premolar teeth with self-ligating passive and control brackets. Conventional brackets presented the highest forces, tip-edge and control brackets showed the lowest. The teeth that suffered the greatest forces were lateral incisors, and those that suffered the least were second premolars.


Assuntos
Braquetes Ortodônticos , Fios Ortodônticos , Desenho de Aparelho Ortodôntico , Aço Inoxidável , Fricção , Análise do Estresse Dentário , Teste de Materiais
4.
Braz. dent. j ; 33(5): 55-63, Sep.-Oct. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1403787

RESUMO

Abstract A new device was developed to enable the visualization and measurement of canine angulation while at the same time visualizing and measuring the force transmitted to adjacent teeth. This study aimed to evaluate the mesiodistal tilt angle of the upper canine brackets, the wire deflection, and its effects on adjacent teeth with five different slot designs of upper canines. Wires (0.020" and 0.019" x 0.025") were tested on different five bracket types at five different distal angles. The force applied to adjacent teeth was measured as the angle was increased, and its consequences were observed in the posterior and anterior regions as well. The force tension (gf) was measured in a universal testing machine. Data were submitted to a 3-way ANOVA and Tukey's test (α=0.05). For both arches, regardless of the type of tooth and bracket type, the highest means tension mean values were shown by the 20° angle, followed by the 15°,10°, and 5° angles, which differed statistically among themselves. Overall, for 5°, 10°, and 15° angles, conventional and versatile brackets showed significantly higher force values in all teeth, tip-edge and control brackets showed the lowest. The highest force values were observed in central and lateral incisors with conventional and versatile brackets and on first and second premolar teeth with self-ligating passive and control brackets. Conventional brackets presented the highest forces, tip-edge and control brackets showed the lowest. The teeth that suffered the greatest forces were lateral incisors, and those that suffered the least were second premolars.


Resumo Foi desenvolvido um novo dispositivo para permitir a visualização e medição da angulação canina ao mesmo tempo que se visualiza e mede a força transmitida aos dentes adjacentes. Este estudo avaliou o ângulo de inclinação mesiodistal dos braquetes caninos superiores, a deflexão do fio, e os seus efeitos nos dentes adjacentes com cinco diferentes desenhos de ranhuras dos caninos superiores. Os fios (0,020" e 0,019" x 0,025") foram testados em cinco diferentes tipos de braquetes e ângulos distais. A força aplicada aos dentes adjacentes foi medida a medida que o ângulo era aumentado, e as suas consequências foram observadas também nas regiões posterior e anterior. A tensão da força (gf) foi medida em uma máquina de ensaio universal (Instron). Os dados foram submetidos ao teste ANOVA 3 fatores e Tukey (α=0,05). Para ambos os arcos, independentemente do tipo de dente e tipo de braquete, os valores médios de tensão mais elevados foram mostrados pelo ângulo de 20°, seguido pelos ângulos de 15°, 10°, e 5°, que diferiram estatisticamente entre si. Em geral, para ângulos de 5°, 10° e 15°, os braquetes convencionais e versáteis apresentaram valores de força significativamente mais elevados em todos os dentes, braquetes tip-edge e controle apresentaram os mais baixos. Os maiores valores de força foram observados nos incisivos centrais e laterais com braquetes convencionais e versáteis e no primeiro e segundo pré-molares com braquetes auto-ligantes passivo e controle. Os braquetes convencionais apresentaram as forças mais elevadas, os braquetes controle e tip-edge apresentaram os valores mais baixos. Os dentes que sofreram as maiores forças foram os incisivos laterais, e os que sofreram menos foram os segundos pré-molares.

5.
J. oral res. (Impresa) ; 11(4): 1-11, jul. 21, 2022. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1426955

RESUMO

Aim: This study aims to evaluate the surface roughness and susceptibility to staining of bleached composite resin with 22% carbamide peroxide, as well as the effect of subsequent prophylaxis with NaHCO3 powder. Material and Methods: Forty disk-shaped (2 × 6 mm) specimens of composite resin (Z250 XT) were prepared. Half of the specimens were subjected to bleaching with 22% carbamide peroxide, and the other half were stored in artificial saliva. In sequence, all specimens were immersed in acai juice (Euterpe oleracea) for 4 h for 14 days, and subdivided into two groups. Group 1 samples were subjected to prophylaxis treatment, while group 2 samples were subjected to treatment with artificial saliva. Surface roughness (Ra) and color (ΔE*) were measured after polishing (T0), bleaching (T1), immersion in acai juice (T2), and application of NaHCO3 powder (T3) using a profilometer and a spectrophotometer. Results: Statistical analyses (analysis of variance and Tukey's test, p≤0.05) revealed that regarding color there was statistically significance for the factors in isolation, except for the factor bleaching. For both color and surface roughness there was statistically significant difference for the interaction, except for the interaction between NaHCO3 power and bleaching. Conclusion: The NaHCO3 air-powder polishing decreases the staining of the composite resin; however, it increases the surface roughness. With respect to the color variable, the whitening factor had no significant effect on the tested material; however, it increases surface roughness.


Objetivo: Este estudio tiene como objetivo evaluar la rugosidad de la superficie y la susceptibilidad a la tinción de la resina compuesta blanqueada con peróxido de carbamida al 22%, así como el efecto de la profilaxis posterior con polvo de NaHCO3. Material y Métodos: Se prepararon cuarenta especímenes en forma de disco (2 × 6 mm) de resina compuesta (Z250 XT). La mitad de los especímenes se sometieron a blanqueo con peróxido de carbamida al 22% y la otra mitad se almacenó en saliva artificial. En secuencia, todos los especímenes se sumergieron en jugo de acai (Euterpe oleracea) durante 4h durante 14 días, y se subdividieron en dos grupos. Las muestras del grupo 1 se sometieron a tratamiento profiláctico, mientras que las muestras del grupo 2 se sometieron a tratamiento con saliva artificial. La rugosidad de la superficie (Ra) y el color (ΔE*) se midieron después del pulido (T0), el blanqueo (T1), la inmersión en jugo de acai (T2) y la aplicación de polvo de NaHCO3 (T3) utilizando un perfilómetro y un espectrofotómetro. Resultados: Los análisis estadísticos (análisis de varianza y prueba de Tukey, p≤0.05) revelaron que en relación al color hubo significancia estadística para los factores en forma aislada, excepto para el factor blanqueamiento. Tanto para el color como para la rugosidad de la superficie hubo una diferencia estadísticamente significativa para la interacción, excepto para la interacción entre el poder de NaHCO3 y el blanqueo. Conclusión: El pulido al aire con polvo de NaHCO3 disminuye el manchado de la resina compuesta; sin embargo, aumenta la rugosidad de la superficie. Con respecto a la variable color, el factor de blanqueamiento no tuvo efecto significativo sobre el material ensayado; sin embargo, aumenta la rugosidad de la superficie.


Assuntos
Humanos , Bicarbonato de Sódio , Resinas Compostas/química , Saliva , Brasil , Cor , Profilaxia Dentária/métodos , Euterpe , Imersão
6.
Dental Press J Orthod ; 26(2): e2119199, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34008739

RESUMO

AIM: To assess the influence of elastomeric ligatures, subjected to a previous in vitro pigmentation process using different substances, on smile aesthetics during orthodontic treatment, from the perception of students and professionals. METHODS: Eight elastomeric ligatures of five commercial brands (3M/Unitek, American Orthodontics, Morelli, Ortho Technology, and Orthometric) (n=8) were immersed in coffee, Coca-Cola, and red wine for one minute per day, for 28 days; and another group of ligatures was immersed in artificial saliva. All samples were photographed and subsequently analyzed using the Adobe Photoshop software, by the RGB method. Afterwards, the pigmented ligatures were inserted in a patient wearing orthodontic brackets, and zoomed photographs of the smile were taken and presented to 40 evaluators, who filled in a satisfaction scale sheet to express their opinion on the smile aesthetics of each photograph. The color data were subjected to analysis of variance (ANOVA) and Tukey tests. RESULTS: The substance with the highest pigmentation potential was coffee (p< 0.05) followed by red wine (p< 0.05). Comparison among the brands used in this study showed that American Orthodontics and Orthometric had the lowest degree of pigmentation when immersed in coffee and red wine (p< 0.05), respectively. However, the brand that showed the highest level of satisfaction among the evaluators was Ortho Technology. CONCLUSIONS: The presence of pigmented elastomeric ligatures affected smile aesthetics, when compared with the control group.


Assuntos
Elastômeros , Braquetes Ortodônticos , Estética Dentária , Humanos , Teste de Materiais , Pigmentação
7.
Dental press j. orthod. (Impr.) ; 26(2): e2119199, 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1249708

RESUMO

ABSTRACT Aim: To assess the influence of elastomeric ligatures, subjected to a previous in vitro pigmentation process using different substances, on smile aesthetics during orthodontic treatment, from the perception of students and professionals. Methods: Eight elastomeric ligatures of five commercial brands (3M/Unitek, American Orthodontics, Morelli, Ortho Technology, and Orthometric) (n=8) were immersed in coffee, Coca-Cola, and red wine for one minute per day, for 28 days; and another group of ligatures was immersed in artificial saliva. All samples were photographed and subsequently analyzed using the Adobe Photoshop software, by the RGB method. Afterwards, the pigmented ligatures were inserted in a patient wearing orthodontic brackets, and zoomed photographs of the smile were taken and presented to 40 evaluators, who filled in a satisfaction scale sheet to express their opinion on the smile aesthetics of each photograph. The color data were subjected to analysis of variance (ANOVA) and Tukey tests. Results: The substance with the highest pigmentation potential was coffee (p< 0.05) followed by red wine (p< 0.05). Comparison among the brands used in this study showed that American Orthodontics and Orthometric had the lowest degree of pigmentation when immersed in coffee and red wine (p< 0.05), respectively. However, the brand that showed the highest level of satisfaction among the evaluators was Ortho Technology. Conclusions: The presence of pigmented elastomeric ligatures affected smile aesthetics, when compared with the control group.


RESUMO Objetivo: Avaliar a influência das ligaduras elásticas submetidas a um processo prévio de pigmentação in vitro, com diferentes substâncias, na estética do sorriso durante o tratamento ortodôntico, segundo a percepção de alunos e profissionais. Métodos: Oito ligaduras elásticas de cinco marcas comerciais (3M Unitek, American Orthodontics, Morelli, Ortho Technology e Orthometric) (n = 8) foram imersas em café, Coca-Cola e vinho tinto por um minuto por dia, por 28 dias, e outro grupo de ligaduras foi imerso em saliva artificial. Todas as amostras foram fotografadas e posteriormente analisadas no software Adobe Photoshop, pelo método RGB. Em seguida, as ligaduras pigmentadas foram inseridas em um paciente com braquetes ortodônticos, e fotografias ampliadas do sorriso foram tiradas e apresentadas a 40 avaliadores, que preencheram uma escala de satisfação para representar sua opinião sobre a estética do sorriso de cada fotografia. Os dados de cor foram submetidos à análise de variância (ANOVA) e testes de Tukey. Resultados: A substância com maior potencial de pigmentação foi o café (p< 0,05), seguido do vinho tinto (p< 0,05). A comparação entre as marcas utilizadas nesse estudo mostrou que a American Orthodontics e a Orthometric apresentaram o menor grau de pigmentação quando imersas em café e vinho tinto (p< 0,05), respectivamente. Porém, a marca que apresentou maior nível de satisfação entre os avaliadores foi a Ortho Technology. Conclusões: A presença de ligaduras elásticas pigmentadas afetou a estética do sorriso, quando comparada à do grupo controle.


Assuntos
Humanos , Braquetes Ortodônticos , Elastômeros , Estética Dentária , Teste de Materiais , Pigmentação
8.
Braz Dent J ; 31(1): 52-56, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32159706

RESUMO

The present study was evaluated the effect of different light activation and thermocycling methods on the shear bond strength (SBS) and on the adhesive remnant index (ARI) of metal brackets bonded to feldspathic ceramic. Hundred metal brackets were bonded to 20 porcelain cylinders, divided into four groups (n=25) based on light activation and thermocycling processes. The cylinders were etched with 10% hydrofluoric acid for 60 s and coated with two layers of silane. The brackets were bonded with Transbond XT composite resin. Light activation in Groups 1 and 3 was performed during 3 s using the VALO Ortho Cordless appliance with irradiance 3,200 mW/cm2 and in Groups 2 and 4 for 40 s using Optilight Max appliance with irradiance 1,200 mW/cm². The samples were stored in deionized water at 37°C for 24 h and the samples from Groups 1 and 2 were submitted to the SBS test at a rate of 1 mm/min, whereas the samples from Groups 3 and 4 were submitted to 7,000 thermal cycles (5°/55°C) before to the SBS test. The data were assessed by two-way analysis of variance and by Tukey's test (a=0.05). No significant difference was observed between SBS means in the different light activation devices used. The samples subjected to thermocycling revealed lower SBS values (p≤0.05). There was predominance of score 0 for ARI in all groups. Therefore, the different light activation methods did not interfere in SBS, but thermocycling reduced SBS.


Assuntos
Colagem Dentária , Braquetes Ortodônticos , Cimentos Dentários , Porcelana Dentária , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento , Propriedades de Superfície
9.
Rev. odontol. UNESP (Online) ; 49: e20200021, 2020. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1139429

RESUMO

Introduction: The sterilization and disinfection procedures should be adapted to the chemical profile of the metal alloys present in the instruments. Objective: This study aimed to perform a micrographic assessment on the surface characteristics of the widia of orthodontic pliers with two alloy compositions subjected to the action of 0.2% peracetic acid and intensive use. Material and method: Twenty distal cutting pliers were divided into two groups (n=10) according to widia composition (%wt): W1- 85% to 87% of tungsten carbide (TC) and other components in the proportion of 13% to 15% and W2 - 87.5% to 88.5% of tungsten carbide and 11.5% to 12.5% for other components. All the pliers were assessed in a stereoscopic magnifying glass (32x) after three treatments: before use (T0); after cutting 100 segments of rectangular stainless-steel wires - intensive use (T1); and after 100 sterilization cycles in 0.2% peracetic acid and intensive use (T2). The cutting sites of all pliers were standardized. Widia regions were defined by line "A" representing T1 and line "B" representing T2. A frequency distribution table and Fisher's exact test (α=0.05) was performed. We assessed two widia from each composition and treatment in SEM and energy-dispersive X-ray spectroscopy (EDS/SEM). Result: The results showed that W1 pliers presented significantly fewer defects after the sterilization cycles with peracetic acid and intensive use than W2 pliers (p=0.0198). There were no differences between both pliers after intensive use (p=1.000). Conclusion: The SEM images and EDS analyses showed changes in widia surfaces after the different treatments. Widia composition affected the resistance of the orthodontic pliers after sterilization cycles with 0.2% peracetic acid and intensive use.


Introdução: Os procedimentos de esterilização e desinfecção devem ser adaptados ao perfil químico das ligas metálicas presentes nos instrumentos. Objetivo: O objetivo do estudo foi realizar uma avaliação micrográfica das características da superfície da widia de alicates ortodônticos com duas composições de ligas submetidas à ação de ácido peracético a 0,2% e uso intensivo. Material e método: Vinte alicates de corte distal foram divididos em dois grupos (n=10), de acordo com a composição widia (% em peso): W1- 85% a 87% de carboneto de tungstênio e outros componentes na proporção de 13% a 15% e W2 - 87,5% a 88,5% de carboneto de tungstênio e 11,5% a 12,5% para outros componentes. Os alicates foram avaliados em uma lupa estereoscópica (32x) após três tratamentos: antes do uso (T0); após corte de 100 segmentos de fios retangulares de aço inoxidável- uso intensivo (T1); após 100 ciclos de esterilização em ácido peracético a 0,2% e uso intensivo (T2). Os locais de corte dos alicates foram definidos pela linha "A" representando T1 e pela linha "B" representando T2. Foi realizada uma tabela de distribuição de frequências e o teste exato de Fisher (α=0,05). As widias foram avaliadas em MEV e Espectroscopia de Energia Dispersiva. Resultado: Os alicates W1 apresentaram defeitos significativamente menores após os ciclos de esterilização com ácido peracético e uso intensivo do que os alicates W2 (p=0,0198). Não houve diferenças entre os dois alicates após uso intensivo (p=1.000). Conclusão: As imagens de MEV/EDS mostraram alterações nas superfícies widia após os diferentes tratamentos. A composição widia afetou a resistência do alicate ortodôntico após ciclos de esterilização com ácido peracético a 0,2% e uso intensivo.


Assuntos
Ortodontia , Análise Espectral , Microscopia Eletrônica de Varredura , Esterilização , Desinfecção , Desinfetantes de Equipamento Odontológico , Instrumentos Odontológicos
10.
Braz. j. oral sci ; 19: e206537, jan.-dez. 2020. tab
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1116566

RESUMO

Aim: To evaluate the influence of social capital on self-perception related to orthodontic treatment need. Methods: A cross-sectional study was conducted with a sample of 578 11-16 years-old adolescents from a city in southern Brazil. Social capital was evaluated using the Social Capital Questionnaire for Adolescent Students (SCQ-AS). Index of Orthodontic Treatment Need (IOTN) assessed malocclusion and self-perception related to orthodontic treatment need. Sociodemographic aspects of adolescents were also evaluated. Individual analyses were performed, relating the study variables to the outcome, estimating the odds ratio with the respective confidence intervals of 95%. The variables with p<0.20 in the individual analyses were tested in the multiple logistic regression models, and those with p<0.10 remained in the model. Results: Social capital did not influence the self-perception related to orthodontic treatment need. Adolescents with high orthodontic needs were 5.35 (CI 95%: 2.68 to 10.65) times more likely to perceived orthodontic treatment need (p <0.05). Crowding and dental absence were associated with self-perception related to orthodontic treatment need (p <0.05). Conclusions: Social capital did not influence the self-perception related to orthodontic treatment need


Assuntos
Humanos , Masculino , Feminino , Adolescente , Ortodontia , Autoimagem , Índice de Necessidade de Tratamento Ortodôntico , Capital Social , Má Oclusão
11.
Rev. odontol. UNESP (Online) ; 48: e20190048, 2019. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1043169

RESUMO

Abstract Introduction In recent years, there has been an increasing demand for esthetic treatments, especially among orthodontic patients. Objective This study determined the fracture strength of monocrystalline and polycrystalline ceramic brackets of different manufacturers during archwire torque. Material and method Sixty ceramic brackets (Roth, right upper central incisors, 0.022 x 0.028-inch slot) were allocated into two groups (30 specimens per group) according to the type of ceramics: monocrystalline and polycrystalline. Subsequently, the groups were divided into three subgroups (n = 10) according to the manufacturer: Orthometric, Eurodonto and Ortho Technology. Sixty PVC cylinders were filled with chemically activated acrylic resin (CAAR), the brackets were fixed with CAAR onto the cylinder surface and the excess material was used to partially cover the base of the bracket. After 24h, the U-shaped wire base (0.019 x 0.025 inches; 6 mm height and width) was inserted into the bracket slot and fixed thereon with a stainless-steel wire. Vertical folds were made at the ends of the "U" to support the universal test machine chisel. The fracture strength test was performed at a speed of 1.0 mm/min until fracture into a universal test machine (Instron). The data were recorded, transformed into g.mm and submitted to two-way ANOVA followed by Tukey's post-hoc test (SAS Institute Inc., Cary, NC, USA, version 9.3) (α=5%). Result Monocrystalline brackets showed a higher fracture strength than polycrystalline brackets, regardless of the manufacturer (p<0.05). The highest fracture strength values were observed in Ortho Technology and Orthometric brackets, with no significant difference between them (p>0.05). Conclusion Monocrystalline ceramic brackets have a higher fracture strength than polycrystalline brackets, with significant manufacturer-dependent differences.


Resumo Introdução A demanda por tratamentos estéticos tem crescido nos últimos anos, sendo cada vez mais forte a preocupação com a estética por parte dos pacientes que buscam o tratamento ortodôntico. Objetivo Este estudo avaliou a resistência à fratura de bráquetes cerâmicos monocristalinos e policristalinos de diferentes fabricantes quando submetidos ao torque do fio. Material e método Sessenta bráquetes cerâmicos (Roth, incisivos centrais superiores direito, canaleta 0,022 x 0,028 polegadas) foram divididos em 2 grupos (30 espécimes por grupo) de acordo com o tipo da cerâmica: monocristalina e policristalina. Posteriomente estes grupos foram divididos em 3 sub-grupos (n=10) de acordo com o fabricante: Orthometric, Eurodonto e Ortho Technology. Segmentos de fio de aço inoxidável retangular (0,019 x 0,025 polegadas) foram dobrados em forma de "U", sendo que a base do "U" foi inserida na canaleta do bráquete e fixado com fio de amarilho em aço inoxidável (0,008mm). Nas extremidades do "U" foram realizadas dobras verticais para servir de apoio para o cinzel da máquina de ensaio universal Instron. O ensaio de resistência à fratura foi realizado à velocidade de 1,0 mm/min até ocorrer a fratura. Os dados foram registrados, transformados em g.mm e submetidos à ANOVA dois fatores e ao teste de Tukey (SAS Institute Inc., Cary, NC, USA, version 9.3) (α=5%). Resultado Os bráquetes monocristalinos apresentaram maior resistência à fratura em relação aos policristalinos, independente do fabricante (p<0,05). Os maiores valores de resistência à fratura foram obtidos com os bráquetes da Ortho Technology e Orthometric, os quais não diferiram estatisticamente entre si (p>0,05). Conclusão Bráquetes monocristalinos possuem maior resistência à fratura em relação aos policristalinos com diferenças na resistência à fratura entre os diferentes fabricantes.


Assuntos
Braquetes Ortodônticos , Torque , Estética Dentária , Técnicas In Vitro
12.
Braz. j. oral sci ; 18: e191605, jan.-dez. 2019. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1095172

RESUMO

Aim: The aim of this study was to verify the frictional force during sliding mechanics in orthodontic tooth movement, using conventional metal brackets of the active and passive self-ligating types with stainless steel and copper nickel titanium archwires. Methods: This experimental in vitro study was conducted with conventional metal (Morelli, Sorocaba, SP, Brazil) brackets, active self-ligated (SLI Morelli, Sorocaba, SP, Brazil) and passive self-ligated (SLP Morelli, Sorocaba, SP, Brazil), with slot 0.022 x 0.028 inches and Roth prescription. The brackets were tested with rectangular section 0.019 x 0.025 inch copper nickel titanium and stainless steel archwires. For each type of bracket, 10 sets of plate/bracket/archwire segment (n=10) were fabricated. Non-parametric Kruskal Wallis and Dunn tests were used for comparison between types of brackets and Wilcoxon tests for comparison between types of archwires. Results: The results showed that the frictional force values were higher with copper nickel titanium than with stainless steel archwires (p<0.05). When copper nickel titanium archwires were used, the active self-ligating brackets showed higher frictional force values than the other types, followed by the conventional brackets. Lower frictional force values were observed with passive self-ligating brackets. For stainless steel archwires, no difference was observed between conventional and active self-ligating brackets, the passive self-ligating type presented lower frictional force values than the others. Conclusion: It was concluded that the higher frictional force was observed when active self-ligating brackets were associated with copper nickel titanium archwires. Lower frictional force was verified between passive self-ligating brackets combined with stainless steel archwires


Assuntos
Braquetes Ortodônticos , Desenho de Aparelho Ortodôntico , Fricção em Ortodontia
13.
Braz. j. oral sci ; 18: e191647, jan.-dez. 2019. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1095367

RESUMO

Aim: The present study aimed to assess, in vitro, the effect of chlorhexidine on the potentiation of polycrystalline ceramic bracket staining. Methods: Seventy-two polycrystalline ceramic brackets of upper right central incisors were divided into six groups (n=12) according to immersion solution. The groups were G1 - distilled water (control); G2 - chlorhexidine; G3 - coffee; G4 - red wine; G5 - chlorhexidine associated with coffee; and G6 - chlorhexidine associated with red wine. The samples were analyzed by means of a spectrophotometer according to the CIEL*a*b* system, and color change (ΔE*) was calculated. The readings were performed at the following times: T0 - After package removal and T1 - After staining. The data were analyzed by Kruskal Wallis and t tests (p<0.05) at 5% significance level. Results: The total color variation (ΔE*) was greater in the group that received chlorhexidine associated with red wine (p<0.05) and lower in the groups that received distilled water. All other groups showed greater value variations when compared to G1 and G2. Group G6 showed a greater color change due to the potentiation of chlorhexidine with the dye substance. Conclusion: It is concluded that chlorhexidine potentiates the staining caused by red wine in polycrystalline ceramic brackets


Assuntos
Cerâmica , Clorexidina , Braquetes Ortodônticos , Antissépticos Bucais
14.
Rev. odontol. UNESP (Online) ; 47(5): 333-339, Sept.-Oct. 2018. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-985722

RESUMO

Introduction: The color stability of resin cements, whether dual-pre-cured or photopolymerizable, as well as the color of the dental substrate, are fundamental for the aesthetic success of ceramic restorations, since the ceramic presents a high level of translucency due to its small thickness. Objective: The aim of this in vitro study was to evaluate the color of a resin cement light polymerized by different light sources and immersed in potentially staining beverages. Material and method: Were made 42 specimens of resin cement Variolink-Esthetic (2×6mm) (n=7), being half polymerized with LED light (F1) and half with Halogen light (F2). The specimens were stored in artificial saliva at 37 °C±1 °C. After 24 hours, they were polished with abrasive discs, and divided for the purpose of being submitted to the different solutions for 2 minutes per day, for 28 days, as follows: S1 - Coca-Cola; S2 - Red Wine; and S3 - Distilled Water (Control). Five color readouts were taken: T0 - initial; T1 - 7 days; T2 - 14 days; T3 - 21 days; and T4 - 28 days; with a spectrophotometer (Model SP62S). The color change data (ΔE*) were submitted to statistical analysis, ANOVA and Tukey (p≤0.05). Result: Analyzing the factor solution, S2 (5.89 (±0.02)), produced a higher ΔE* value than S1 (3.79 (±0.02)) and (S1), a higher value than S3 (1.41 (±0.02)). Analyzing the factor light source, F2 (4.05 (±0.12)), produced a higher ΔE* value than F1 (3.33 (±0.12)). When analyzing the factor time, ΔE* values were found to increase gradually over the course of time: T1(2.36 (±0.08)); T2(3.27 (±0.08)); T3(4.06 (±0.08)); and T4(5.09 (±0.08)). Conclusion: It was concluded that red wine produced a greater color change; Halogen light promoted highest degree of pigmentation; and the longer the time of immersion, the greater the color change of the material.


Introdução: A estabilidade de cor dos cimentos resinosos, sejam eles de presa dual ou fotopolimerizáveis, assim como a cor do substrato dental, são fundamentais para o sucesso estético das restaurações cerâmicas uma vez que a cerâmica apresenta alto nível de translucidez devido a sua pequena espessura. Objetivo: O objetivo deste estudo in vitro foi avaliar a cor de um cimento resinoso fotopolimerizado por diferentes fontes de luz e imersos em bebidas potencialmente corantes. Material e método: Foram confeccionados 42 espécimes do cimento resinoso Variolink-Esthetic (2×6mm) (n=7), sendo metade fotopolimerizado com luz LED (F1) e metade com luz Halógena (F2). Os espécimes foram mantidos em saliva artificial à 37 °C±1 °C. Após 24 horas, foram polidos com discos abrasivos e subdivididos para serem imersos 2 minutos por dia, durante 28 dias, nas diferentes soluções: S1 - Coca-Cola; S2 - Vinho Tinto; e S3 - Água destilada (controle). Foram realizadas 5 leituras de cor: T0 - inicial; T1 - 7 dias; T2 - 14 dias; T3 - 21 dias; e T4 - 28 dias; com auxílio de um espectrofotômetro (modelo SP62S). Os dados de alteração de cor (ΔE*) foram submetidos a análise estatística, ANOVA e Tukey (p≤0,05). Resultado: Analisando o fator solução, S2 (5,89 (±0,02)), proporcionou maior ΔE* que S1 (3,79 (±0,02)) e este (S1), maior que S3 (1,41 (±0,02)). Analisando o fator fonte de luz, F2 (4,05 (±0,12)), proporcionou maior ΔE* que F1 (3,33 (±0,12)). E analisando o fator tempo, obteve-se que ΔE* foi gradativamente aumentando no decorrer do tempo: T1(2,36 (±0,08)); T2(3,27 (±0,08)); T3(4,06 (±0,08)); e T4(5,09 (±0,08)). Conclusão: Conclui-se que o vinho tinto promoveu maior alteração de cor; a luz Halógena promoveu maior pigmentação e; quanto maior o tempo de imersão, maior alteração de cor do material.


Assuntos
Saliva , Técnicas In Vitro , Cor , Cimentos de Resina , Cura Luminosa de Adesivos Dentários , Reparação de Restauração Dentária , Luz , Vinho , Pigmentação , Espectrofotômetros , Análise de Variância , Corantes
15.
Braz. j. oral sci ; 17: e18885, 2018. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-970570

RESUMO

Aim: The objective of this study was to measure and compare the in vitro performance of active and passive self-ligating brackets in orthodontic rotation by means of an electromagneticfield simulation. Methods: The study sample consisted of 32 mandibular right central incisor brackets (n=8), slot 0.022", that were divided into the following groups: 1) BioQuick® (Forestadent, Pforzheim, Germany) active brackets; 2) In- Ovation®R (Dentsply-GAC, Central Islip, New York, USA) active brackets; 3) Damon-Q® (Ormco, Orange, California, USA) passive brackets, and 4) Smartclip® (3M, Monrovia, California, USA) passive brackets. The orthodontic wire used was CuNiTi round section 0.016", thermoactivated at 35o C (ORMCO- Orthodontics Glendora, California, USA). The experiment wasperformed in a simulator machine, composed of two fixedlateral axes and a movable central axis, which simulated the dental rotation. Qualitative analysis (n = 4) was performed using SEM. After the descriptive and exploratory analysis, the yield and grade data were submitted to one-way analysis of variance (ANOVA) followed by the Tukey test, considering the level ofsignificance of 5%. Results: In-Ovation®R brackets showedsignificantly higher yield than BioQuick® and Damon-Q®. Damon-Q® brackets presented a significantly lower mean valuethan In-Ovation R and Smartclip®. BioQuick® did not differsignificantly from Damon-Q® and Smartclip®. In-Ovation®R did not differ significantly from Smartclip®. Conclusion: In the present study, it was observed that there is a difference in rotational control in the different self-ligating brackets tested being the best rotational control was the In-Ovation R® group (active), followed in descending order by the groups Smartclip® (passive), Bioquick® (active) and Damon Q® (passive)


Assuntos
Rotação , Braquetes Ortodônticos , Campos Eletromagnéticos
16.
Rev. odontol. UNESP (Online) ; 46(3): 179-183, May-June 2017. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-902650

RESUMO

Objective: To evaluate in vitro the effect of different treatments of the ceramic surface and thermal cycling on the shear bond strength (SBS) of metallic brackets bonded to feldspathic ceramic. Material and method: Ceramic cylinders were divided into four groups (n=4) according to the treatment of ceramic surface: G1-Clearfil Ceramic Primer silane and Transbond XT (CCPT); G2-etched with 10% hydrofluoric acid (HFA) for 60 s, CCP and Transbond XT (ACCPT); G3-etched with 10% HFA for 60 s, Ambar Adhesive and Transbond XT (AAAT); and, G4 - etched with 10% HFA for 60 s, RelyX Ceramic Primer silane -RCP, adhesive primer Transbond and Transbond XT (ACPPT). Brackets were bonded to the cylinders with Transbond XT and light-activated for 40 s with LED Radii Plus. All specimens were stored in deionized water at 37 °C for 24 h, and two cylinders from each group were subject to 7,000 thermal cycles in a thermal cycler (5 °C/55 °C). After storage and thermal cycling, the SBS test was performed at a crosshead speed of 1 mm/min. Data were subjected to two-way ANOVA and Tukey's post hoc test (α=0.05). Result: The SBS of ACCPT was significantly higher than the other groups (p<0.05). The specimens submitted to thermal cycling showed significantly lower SBS than those without thermal cycling (p<0.05), regardless the ceramic surface treatment. The ARI showed predominance of score 0 for all groups. Conclusion: Acid etching, CCP silane and Transbond XT method obtained the best results for bracket bonding. Thermal cycling reduced SBS for all groups. Score 0 was predominant for ARI in all groups.


Objetivo: Avaliar in vitro o efeito de diferentes tratamentos de superfície da cerâmica e ciclagem térmica na resistência da união ao cisalhamento (RUC) de bráquetes metálicos colados na cerâmica felspática. Material e método: Cilindros cerâmicos foram separados em 4 grupos (n=4) de acordo com os tratamentos da superfície da cerâmica: G1-Clearfil Ceramic Primer silano e Transbond XT (CCPT); G-condicionamento com ácido hidrofluorídrico a 10% (AHF) por 60s, CCP e Transbond XT (ACCPT); G3-condicionamento com AHF a 10% por 60s, Adesivo Ambar e Transbond XT (AAAT); e, G4 condicionamento com AHF a 10% por 60s, RelyX Ceramic Primer silano, primer adesivo Transbond e Transbond XT (ACPAT). Os bráquetes foram fixados nos cilindros com Transbond XT e fotoativado por 40s com LED Radii Plus. Todas as amostras foram armazenadas em água deionizada a 37 °C por 24 h e dois cilindros de cada grupo foram submetidos a 7.000 ciclos térmicos na máquina para ciclagem térmica (5 °C/55 °C). Após armazenagem e ciclagem térmica, a RUC foi realizada à velocidade de 1 mm/min. Na Análise de Variância de 2 fatores e ao teste de Tukey's post hoc test (α=0,05) a RUC do G2 foi significante maior do que dos demais grupos (p<0,05). Resultado: As amostras submetidas à ciclagem térmica apresentaram valores de RUC significantemente menores do que as amostras sem ciclagem térmica (p<0,05), independente do tratamento de superfície da cerâmica. Conclusão: Nas condições desse estudo o melhor resultado para colagem foi obtido com o condicionamento, silano CCP e Transbond XT. A ciclagem térmica reduziu a RUC em todos os grupos.


Assuntos
Silanos , Cerâmica , Análise de Variância , Braquetes Ortodônticos , Cimentos Dentários , Resistência ao Cisalhamento , Técnicas In Vitro , Colagem Dentária
17.
Braz. j. oral sci ; 15(2): 176-179, Apr.-June 2016. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-848381

RESUMO

Aim: This in vitro study investigated the effect of the application of an adhesive, silane and thermal cycling (TC) on the shear bond strength (SBS) of ceramic brackets to feldspathic ceramic. Methods: 16 cylinders of feldspathic ceramic were etched with hydrofluoric acid and divided into four groups (n=4): G1 - silane, without TC; G2 ­ silane, with TC; G3 - adhesive, without TC; G4 - adhesive, with TC. One layer of silane was applied on the surface of cylinders in G1 and G2 e one layer of photo-activated adhesive Single Bond Universal was used in G3 and G4. Ceramic brackets were bonded using Transbond XT. The SBS data were subjected to two-way ANOVA and Tukey's post hoc test (α=0.05). The Adhesive Remnant Index (ARI) was evaluated at 40× magnification. Results: Silane was more effective than adhesive on the SBS of the brackets to ceramic (p<0.05). TC decreased significantly the SBS values compared with the groups without TC (p<0.05). The ARI results showed predominance of score 0. Conclusions: Groups with silane showed higher SBS than groups with adhesive. TC influence significantly on the bond strength. Regarding ARI, score 0 predominated in all groups (Au)


Assuntos
Adesivos , Análise de Variância , Cerâmica , Odontologia , Resistência ao Cisalhamento , Silanos
18.
Braz. dent. j ; 26(3): 268-271, May-Jun/2015. tab
Artigo em Inglês | LILACS | ID: lil-751860

RESUMO

The purpose of this study was to determine the influence of hydrochloric acid on surface roughness of composite resins subjected to brushing. Sixty samples measuring 2 mm thick x 6 mm diameter were prepared and used as experimental units. The study presented a 3x2 factorial design, in which the factors were composite resin (n=20), at 3 levels: microhybrid composite (Z100), nanofilled composite (FiltekTM Supreme), nanohybrid composite (Ice), and acid challenge (n=10) at 2 levels: absence and presence. Acid challenge was performed by immersion of specimens in hydrochloric acid (pH 1.2) for 1 min, 4 times per day for 7 days. The specimens not subjected to acid challenge were stored in 15 mL of artificial saliva at 37 oC. Afterwards, all specimens were submitted to abrasive challenge by a brushing cycle performed with a 200 g weight at a speed of 356 rpm, totaling 17.8 cycles. Surface roughness measurements (Ra) were performed and analyzed by ANOVA and Tukey test (p≤0.05). Surface roughness values were higher in the presence (1.07±0.24) as compared with the absence of hydrochloric acid (0.72±0.04). Surface roughness values were higher for microhybrid (1.01±0.27) compared with nanofilled (0.68 ±0.09) and nanohybrid (0.48±0.15) composites when the specimens were not subjects to acid challenge. In the presence of hydrochloric acid, microhybrid (1.26±0.28) and nanofilled (1.18±0,30) composites presents higher surface roughness values compared with nanohybrid (0.77±0.15). The hydrochloric acid affected the surface roughness of composite resin subjected to brushing.


Este estudo avaliou a influencia do ácido clorídrico na rugosidade superficial de resinas compostas submetidas a escovação. Sessenta corpos de prova medindo 2 mm de espessura x 6 mm de diâmetro foram confeccionados e utilizados como unidades experimentais. O presente estudo envolve uma análise fatorial 3x2, onde os fatores foram resina composta (n=20), com 3 níveis: resina composta microhíbrida (Z100), nanoparticulada (Filtek TM Supreme) e nanohíbrida (Ice); e desafio ácido (n=10), com 2 níveis: ausência e presença. O desafio ácido foi realizado por meio da imersão em ácido clorídrico (pH 1,2) por 4 h diárias, 1 min cada imersão, durante 7 dias. Os espécimes que não foram submetidos ao desafio ácido foram armazenados em 15 mL de saliva artificial a 37 °C. Todos os espécimes foram submetidos ao desafio abrasivo. O processo de escovação foi realizado com 200 g de peso, com velocidade de 356 rpm, totalizando 17,8 ciclos. As medidas de rugosidade superficial (Ra) foram realizadas e analisadas por meio da ANOVA e teste de Tukey (p<0,05). Os valores de rugosidade superficial foram maiores na presença (1,07±0,24)quando comparado com a ausencia do ácido hidroclorídrico (0,72±0,04). A resina microhíbrida (1,01±0,27) apresentou maior rugosidade superficial que as resinas nanoparticulada (0,68±0,09) e nanohíbrida (0,48±0,15) quando os espécimes não foram submetidos ao desafio ácido. Na presença do ácido hidroclorídrico, a resina microhíbrida (1,26±0,28) e a resina nanoparticulada (1,18±0,30) apresentou maior valor de rugosidade superficia comparado com a resina nanohíbrida (0.77±0.15). O ácido hidroclorídrico influenciou a rugosidade superficial da resina composta submetida a escovação.


Assuntos
Resinas Compostas , Ácido Clorídrico/química , Concentração de Íons de Hidrogênio , Saliva , Propriedades de Superfície
19.
Braz. oral res ; 26(3): 209-214, May-June 2012. tab
Artigo em Inglês | LILACS | ID: lil-622935

RESUMO

The aim of this study was to determine the influence of mouthrinses on the surface roughness of a nanofilled composite resin after toothbrushing. One hundred nanofilled composite resin specimens were prepared and randomly distributed into two groups-brushed and non-brushed-and then assigned to five subgroups, according to the mouthrinse solutions (n = 10): Colgate Plax Fresh Mint, Oral B, Cepacol, Colgate Plax, and artificial saliva. Each sample was immersed in 20 mL of the mouthrinses for 1 minute, 5 days per week, twice a day, for a 3-week period. The control group used in the study was one in which the specimens were not subjected to brushing and remained only in artificial saliva. Toothbrushing was performed once a week for 1 minute, for 3 weeks. Surface roughness measurements (Ra) were performed after the immersion period and toothbrushing, by means of a profilometer. Data were analyzed by two-way ANOVA and Tukey's test. Analysis revealed that the association between toothbrushing and Colgate Plax Fresh Mint produced the lowest surface roughness (p < 0.05). All other groups tested (Oral B, Cepacol, Colgate Plax, artificial saliva) exhibited no statistically significant differences between surfaces, whether subjected to toothbrushing or not (p < 0.05). It was concluded that the surface roughness of the nanofilled composite resin tested can be influenced by the mouthrinse associated with toothbrushing.


Assuntos
Humanos , Resinas Compostas/química , Antissépticos Bucais/química , Nanocompostos/química , Escovação Dentária , Análise de Variância , Imersão , Teste de Materiais , Distribuição Aleatória , Propriedades de Superfície , Saliva Artificial/química , Fatores de Tempo , Abrasão Dentária
20.
Braz Oral Res ; 26(3): 209-14, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22641439

RESUMO

The aim of this study was to determine the influence of mouthrinses on the surface roughness of a nanofilled composite resin after toothbrushing. One hundred nanofilled composite resin specimens were prepared and randomly distributed into two groups-brushed and non-brushed-and then assigned to five subgroups, according to the mouthrinse solutions (n = 10): Colgate Plax Fresh Mint, Oral B, Cepacol, Colgate Plax, and artificial saliva. Each sample was immersed in 20 mL of the mouthrinses for 1 minute, 5 days per week, twice a day, for a 3-week period. The control group used in the study was one in which the specimens were not subjected to brushing and remained only in artificial saliva. Toothbrushing was performed once a week for 1 minute, for 3 weeks. Surface roughness measurements (Ra) were performed after the immersion period and toothbrushing, by means of a profilometer. Data were analyzed by two-way ANOVA and Tukey's test. Analysis revealed that the association between toothbrushing and Colgate Plax Fresh Mint produced the lowest surface roughness (p < 0.05). All other groups tested (Oral B, Cepacol, Colgate Plax, artificial saliva) exhibited no statistically significant differences between surfaces, whether subjected to toothbrushing or not (p < 0.05). It was concluded that the surface roughness of the nanofilled composite resin tested can be influenced by the mouthrinse associated with toothbrushing.


Assuntos
Resinas Compostas/química , Antissépticos Bucais/química , Nanocompostos/química , Escovação Dentária , Análise de Variância , Humanos , Imersão , Teste de Materiais , Distribuição Aleatória , Saliva Artificial/química , Propriedades de Superfície , Fatores de Tempo , Abrasão Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...